Digital Manifold Fieldpiece SMAN460

partnr: 15962
contact us
Digital Manifold Fieldpiece SMAN460

Product information

The SMAN460 wireless four-port digital manifold is the top-of-the-line Fieldpiece manifold. It has more features and benefits than any other manifold on the market. With target superheat automatically calculated, simultaneous superheat and subcooling, all 9 measurements displayed on the large, easy-to-read screen, extra large 3/8' full bore and 4th VAC port, and wireless measurements for real-time system diagnosis and charging, the SMAN460 is the manifold HVACR pros trust to do more.

Plus it has a built in micron vacuum gauge with gives technicians the ability to set high and low alarms, and a stopwatch, as well as view the micron rate of change.

Pressure

Sensor type: Absolute pressure sensors
Connector type: Standard 1/4" and 3/8" NPT male flare fitting
Range: 29” HgV to 580psig (English), 74 cmHgV to 0 to 4000KPa
(Metric), 4.000MPa (Metric), and 40.00bar (Metric)
Resolution: 0.1 psi/inHg; 1 kPa/cmHg; 0.001MPa; 0.01bar
Accuracy: 29” HgV to 0” HgV: ±0.2” HgV
74 cmHgV to 0 cmHgV: ±1 cmHgV
0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa:
±0.007MPa; 0 to 13.78 bar ±0.07 bar
200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of
reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa);
13.78 to 40.00bar: ±(0.3% of reading +0.07bar)
Maximum overload pressure: 800 psig
Units: Psig, kPa, MPa, bar, inHg, and cmHg

Microns for Vacuum

Connector type: Standard 1/4" and 3/8" NPT male flare fitting
Range: 0 to 9999 microns of mercury
Resolution: 1 micron (0 to 2000 microns), 250 microns (2001 to
5000 microns), 500 microns (5001 to 8000 microns), 1000 microns
(8001 to 9999 microns)
Accuracy: ±(5% of reading + 5 microns), 50 to 1000 microns
Maximum overload pressure: 580 psig
Units: Microns of mercury

Temperature

Sensor type: Type K thermocouple
Range: -95°F to 999.9°F (-70°C to 537.0°C)
Resolution: 0.1°F/°C
Accuracy: ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C
±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C
Note: All accuracies are after a field calibration.

General

Mini-USB port: For updating to newer versions of firmware
Display size: 5 inches (diagonal)
Backlight: Blue (On for 3 minute unless turned off manually)
Battery: 6 x AA (Battery life below based on alkaline type)
Battery life: 350 hours (without vacuum, backlight and wireless)
Low battery indication: is displayed when the battery
voltage drops below the operating level
Auto shut off: 30 minutes of inactivity when APO is activated
Over range: "OL" or "-OL" is displayed
Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH
Temperature coefficient: 0.1 x (specified accuracy) per °C (0°C to
18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F
Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH
(with battery removed)
Weight: 4.03 lbs (1.83 kg)

Wireless

Wireless range: 1 to 100 feet (30m)
Initial sync setup range: 1 to 10 feet
Wirelessly transmit to Fieldpiece HVAC Guide® HG3 System Analyzer
Wirelessly receive indoor wet bulb (IDWB) and outdoor dry bulb
(ODDB) from Fieldpiece transmitters