The Fieldpiece SMAN440 is a 4-port, wireless digital manifold with a large 3/8" port for faster evacuations and recovery.
For the digital manifold you can order the hoses separately under the following article numbers:
14845: Hose 3/8" yellow 3/8"FF str. x 3/8"FF str. 0.90 mtr
11852: Hose Set 1/4" str. x 1/4" vlv 3 ft. - 0.90m
Measures:
Calculates:
Specifications
Mini-USB port: For updating to newer versions of firmware Display
Size: 5 inches (diagonal)
Backlight: Blue (On for 3 minute unless turned off manually)
Battery: 6 x AA (Battery life below based on alkaline type)
Battery life: 350 hours (without backlight and wireless)
Low battery indication: is displayed when the battery voltage drops below the operating level
Auto shut off: 30 minutes of inactivity when APO is activated
Over range: "OL" or "-OL" is displayed
Operating environment: 32°F to 122°F (0°C to 50°C) at <75% RH
Temperature coefficient: 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C), per 0.6°F (32°F to 64°F, 82°F to 122°F Storage temperature: -4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed) Weight: 4.03 lbs (1.83 kg)
Pressure
Sensor type: Absolute pressure sensors
Connector type: Standard 1/4" and 3/8" NPT male flare fitting
Range: 29” HgV to 580psig (English), 74 cmHgV to 0 to 4000KPa (Metric), 4.000MPa (Metric), and 40.00bar (Metric)
Resolution: 0.1 psi/inHg; 1 kPa/cmHg; 0.001MPa; 0.01bar
Accuracy: 29” HgV to 0” HgV: ±0.2” HgV 74 cmHgV to 0 cmHgV: ±1 cmHgV 0 to 200 Psig: ±1 Psi; 0 to 1378 KPa: ±7 KPa; 0 to 1.378MPa: ±0.007MPa; 0 to 13.78 bar ±0.07 bar 200 to 580 Psig: ±(0.3% of reading+1 Psig); 1378 to 4000KPa: ±(0.3% of reading+7 Kpa); 1.378 to 4.000MPa: ±(0.3% of reading+0.007MPa); 13.78 to 40.00bar: ±(0.3% of reading +0.07bar)
Maximum overload pressure: 800 psig
Units: Psig, kPa, MPa, bar, inHg, and cmHg
Temperature
Sensor type: Type K thermocouple Range: -95°F to 999.9°F (-70°C to 537.0°C) Resolution: 0.1°F/°C Accuracy: ±(1.0°F) -95°F to 199.9°F; ±(0.5°C) -70°C to 93°C ±(2.0°F) 200°F to 999.9°F; ±(1.0°C) 93°C to 537.0°C Note: All accuracies are after a field calibration.
Wireless
Wireless range: 1 to 100 feet (30m) Initial sync setup range: 1 to 10 feet Wirelessly transmit to Fieldpiece HVAC Guide® HG3 System Analyzer Wirelessly receive indoor wet bulb (IDWB) and outdoor dry bulb (ODDB) from Fieldpiece transmitters
Refrigerants
The P-T charts of the following 45 refrigerants come pre-programmed into your SMAN. In your SMAN the refrigerants are listed in order of most commonly used. Here, they are listed in numerical order for easy reference. Periodically we program new refrigerants in SMAN™ Manifold, go to www.fieldpiece.com/support/downloads for newly added refrigerants for the SMAN™ Manifolds via firmware update.
R11, R113, R114, R12, R123, R1234YF, R124, R125, R13, R134A, R22, R23, R32, R401A(MP39), R401B, R402A, R402B, R404A, R406A, R407A, R407C, R407F, R408A, R409A, R410A, R414B (Hotshot), R416A, R417A, R417C (HOT SHOT 2), R420A, R421A, R421B, R422A, R422B(NU22B), R422C(Oneshot), R422D, R424A, R427A, R434A(RS-45), R438A(MO99), R500, R502, R503, R507A, R508B (Suva95)